EBM
6100-3-WP |
 |
Compression load cells 
|
cylindrical
|
waterproof IP68
deep-sea application execution
|
| Measuring
fields |
· |
from
0/5 kg
to 0/1,000 t
(see table MODELS) |
| Depth
of application |
·
|
Certifiable up to 100 m (10 bar) |
| Nominal sensitivity |
·
|
2 mV/V f.s. (*) |
| Overload |
·
|
up to 120% e.o.s. (in linearity) |
| Deflection (e.o.s.) |
·
|
0.035 mm (nominal) |
| Excitation |
·
|
10 V (recommended), max 15 V |
| Bridge |
·
|
4 x 600 ohm (nominal) |
| Linearity |
·
|
0.15% e.o.s. |
| Hysteresis |
·
|
0.15% e.o.s. |
| Temperature
effect on zero |
· |
<
0.005 % e.o.s./ºC |
| Temperature
effect on output |
·
|
< 0.005 % of the measured value/ºC |
| Compensated
temperature |
· |
from
-20 to 80 ºC |
| Operating
temperature |
· |
from
-30 to 90 ºC (over upon request) |
| Material |
·
|
stainless steel 4122 |
| Natural frequency |
·
|
from 4 to 10 kHz |
| Electric
connection |
·
|
deep-sea
waterproof cable (IP68) (**) |
(*)
Each load cell comes with an
individual calibration certificate (issued by the manufacturer), with the
exact value of the sensitivity.
(**)
The load cells are available
also in execution with IP 67 cable, or with MIL (IP65) connector, or with
Tuchel connector (for standard room application) (see page EBM 6100-3).
|
MODEL
|
MEASURING FIELD
(0 / kg)
|
D
(mm)
|
H1
(mm) |
H2
(mm)
|
A
(mm)
|
|
|
|
|
|
|
| EBM 6136-WP |
5 t |
35 |
40 |
57.5 |
25 |
| EBM 6137-WP |
10 t |
35 |
40 |
57.5 |
25 |
| EBM 6138-WP |
20 t |
44 |
45 |
67 |
30 |
| EBM 6139-WP |
50 t |
54 |
50 |
77 |
35 |
| EBM 6140-WP |
100 t |
74 |
70 |
107 |
35 |
| EBM 6141-WP |
200 t |
99 |
100 |
150 |
50 |
| EBM 6142-WP |
500 t |
157 |
135 |
-
|
67.5 |
| EBM 6440-WP |
1,000 t |
220 |
160 |
-
|
82 |
.
Where indicated (see table above),
the load cells are available in execution with height "H1" (flat loading
surface), or "H2" (convex loading surface).
.
All the load cells are available
with threaded base (on the outer diameter "D") for clamping.
| . |
|
. |
|
|
|